We appreciate your interest in part number 713.1202, which is currently available for purchase here on Jet Force Aero. For your reference, this item is produced by Toroid Corp and is listed with the NSN 6120-01-469-9388, as well as the description “Transformer Power.” If this matches your requirements, we encourage you to fill out the Request for Quote (RFQ) form featured on this page to receive tailored purchasing options on part number 713.1202. All that we ask is that you submit as many details about your procurement needs as possible, such as your desired quantity, budget, and anticipated fulfillment timeframe, as this will enable our specialists to craft an ideal response for you.
Note : We Will Not Share Your Information With Any Third Parties.
In addition to part number 713.1202, be sure to explore our website further for related items produced by Toroid Corp under the CAGE Code 0FZR3 as you wish. We also feature catalogs to help you find additional options that are categorized under FSC 6120 Transformers Distribution and Power Station and the NSN 6120-01-469-9388. Regardless of which NSN parts you need from us, rest assured that we will always treat you to affordable solutions where you never have to sacrifice quality or prompt fulfillment. We are ready to assist you with all your sourcing needs, so kick off quotation at your convenience.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6120-01-469-9388 Item PartTypeName: TRANSFORMER,POWER | 6120 | 014699388 | N | A | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| A | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| CTR015 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABTB | Mounting Hole Diameter | 0.250 INCHES NOMINAL SINGLE GROUP |
| CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CBBL | Features Provided | COLOR CODED LEAD AND PROTECTIVE COVER AND SPECIAL MARKING |
| ADAU | Body Height | 1.900 INCHES NOMINAL |
| ACZB | Frequency Rating | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| CRBZ | Winding Operating Current | 0.6 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
| CRBZ | Winding Operating Current | 0.7 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 1.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| ACZF | Maximum Transformer Power Rating | 150.0 VOLT-AMPERE SINGLE COMPONENT |
| AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
| FEAT | Special Features | SUPPLY VOLTAGE RANGE IS PLUS OR MINUS 10 PERCENT; PRIMARIES ARE INSIDE SLEEVE AND MUST BE CONNECTED TOGETHER IN SERIES OR PARALLEL; PRIMARY LEAD WIRES ARE MAGNET WIRE SELF-LEADS, 24 GAUGE, 8.000 IN. LENGTH NOMINAL; SECONDARY LEAD WIRES ARE MULTI-STRANDED, 22 GAUGE, 8.000 IN. LENGTH NOMINAL; CORE NO. 900140, NO-LOAD LOSS EQUALS 0.9 WATT , NO-LOAD AMPERAGE EQUALS 8.7 MILLIAMPS; UL RECOGNIZED TO UL 1411 AND CSA CERTIFIED TO CSA C22.2, NO. 66 |
| ADAR | Body Outside Diameter | 3.900 INCHES NOMINAL |
| MRC | Decoded Requirement | Clear Text Reply |
| AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
| CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| AARG | Reliability Indicator | NOT ESTABLISHED |
| AKNA | Inclosure Type | FULLY INCLOSED |