We appreciate your interest in part number S4993, which is currently available for purchase here on Jet Force Aero. For your reference, this item is produced by Vishay Hirel Systems Llc and is listed with the NSN 5950-00-843-0261, as well as the description “Reactor Transformer.” If this matches your requirements, we encourage you to fill out the Request for Quote (RFQ) form featured on this page to receive tailored purchasing options on part number S4993. All that we ask is that you submit as many details about your procurement needs as possible, such as your desired quantity, budget, and anticipated fulfillment timeframe, as this will enable our specialists to craft an ideal response for you.
Note : We Will Not Share Your Information With Any Third Parties.
In addition to part number S4993, be sure to explore our website further for related items produced by Vishay Hirel Systems Llc under the CAGE Code 80023 as you wish. We also feature catalogs to help you find additional options that are categorized under FSC 5950 Coils and Transformers and the NSN 5950-00-843-0261. Regardless of which NSN parts you need from us, rest assured that we will always treat you to affordable solutions where you never have to sacrifice quality or prompt fulfillment. We are ready to assist you with all your sourcing needs, so kick off quotation at your convenience.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-00-843-0261 Item PartTypeName: REACTOR-TRANSFORMER | 5950 | 008430261 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 7901305-00 | 6 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING |
| BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 43.50 AC VOLTS NOMINAL 2ND COMPONENT SINGLE SECONDARY |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 33 THREADED STUD |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 10.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.880 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACYV | INDUCTANCE RATING | 700.00 MICROHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE PRIMARY |
| CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 40.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING |
| CWJS | WINDING OPERATING VOLTAGE | 104.60 AC VOLTS MINIMUM 2ND COMPONENT SINGLE PRIMARY AND 125.40 AC VOLTS MAXIMUM 2ND COMPONENT SINGLE PRIMARY |
| FEAT | SPECIAL FEATURES | 3 PHASE DELTA PRIMARY; 6 PHASE STAR SECONDARY |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 11.380 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 4.250 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 4.880 INCHES NOMINAL |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENT |
| AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.